In the case of special industrial technologies, it may be justified to determine the material properties by deviating from the standardized test conditions. We carry out our measurements according to the specific needs of our partners. Our most common special measurements in the area of explosion safety:

  • Elevated temperature blast chamber test

We can carry out blast chamber tests with jacket heating up to 200°C.

  • Limit concentration for inert atmosphere (LOC)

Our test is carried out in relation to carbon dioxide or nitrogen.

  • Test of hybrid mixtures

Determining the explosive properties in the case of the simultaneous presence of dust and gas explosion hazards.

  • Definition of Svel Point

The Svel point of a solid substance is the lowest temperature at which enough combustible gas or steam is produced that it ignites when mixed with oxygen by an electric spark.

In case of a special inspection request, contact us by phone, email, or via our contact form and request our unique offer.